| Category | Component | Technical Details & Material Specifications |
|---|---|---|
| Structure | Main Frame | High-strength Q235B Galvanized Steel (Hot-dip treated) |
| Main Beam | 80 × 100 × 2.5 mm Galvanized Square Tube | |
| Vertical Column | 150 × 150 × 2.0 mm Galvanized Square Tube | |
| Sub-frame | 40 × 60 × 2.5 mm Galvanized Square Tube | |
| Hardware | 4mm Galvanized Lifting Lugs & Reinforced Industrial Hinges | |
| Insulation | Exterior Walls | 75mm Sandwich Panel (Dual-sided 0.426mm color-coated steel) |
| Roof & Partitions | 50mm Sandwich Panel (Dual-sided 0.426mm color-coated steel) | |
| Core Density | Standard high-performance insulation: 40kg/m³ | |
| Internal Wall | 15mm Decorative Metal Sheet + 9mm Anti-collision Strips | |
| Flooring | Main Floor | 15mm Cement Fiber Board (Fireproof & Moisture-resistant) |
| Lateral Floor | 18mm Industrial Grade Construction Form-work | |
| Electrical | System Switch | High-standard 2P 63A Main Circuit Breaker |
| Lighting | 6x High-efficiency Three-proof LED Ceiling Lights | |
| Compliance | Sockets and wiring customizable to UL / CE / SAA standards | |
| Bespoke Customization Solutions | ||
| Layout Custom | ✦ 100% Flexible Layout: Our engineering team can modify internal partitions, door positions, and window placements based on your specific floor plans and drawings. | |
| Dimensions | ✦ Adjustable Sizes: Beyond standard 20ft/40ft models, custom lengths, widths, and heights are available to match your project requirements. | |
| Surface Finish | ✦ Optional Aesthetics: Multiple exterior colors (RAL System) and textures (Wood Grain, Marble, or Industrial Metal) are available. | |
?
Frequently Asked Questions
Q
What type of steel is used for the main frame, and why is it hot-dip galvanized?
The main frame is constructed from high-strength Q235B Galvanized Steel that has been hot-dip treated. Hot-dip galvanizing provides a thick, metallurgically bonded zinc coating that offers superior corrosion resistance compared to standard paint or electro-galvanized finishes — making the structure highly durable in outdoor and harsh environments.
Q
What is the difference between the 75mm and 50mm sandwich panels used in this unit?
The 75mm sandwich panels are used for exterior walls where greater thermal insulation and structural rigidity are required. The 50mm sandwich panels are applied to the roof and internal partitions, where the load requirements are lower. Both use 0.426mm dual-sided color-coated steel with a 40 kg/m³ high-performance insulation core.
Q
Is the flooring fireproof and moisture-resistant?
Yes. The main floor uses 15mm Cement Fiber Board, which is engineered to be both fireproof and moisture-resistant, making it well-suited for demanding site conditions. The lateral floor uses 18mm industrial-grade construction formwork for additional load-bearing support.
Q
Can the electrical system be customized to meet international safety standards?
Absolutely. The electrical system is fully adaptable. All sockets and wiring can be configured to comply with UL (United States), CE (Europe), or SAA (Australia) standards. The unit also comes equipped with a high-standard 2P 63A main circuit breaker and six three-proof LED ceiling lights as standard.
Q
Can I request a layout that differs from standard floor plans?
Yes. The unit supports 100% flexible layout customization. The engineering team is able to adjust internal partitions, relocate doors and windows, and tailor the internal configuration based on your provided drawings or project-specific requirements — with no compromise on structural integrity.
Q
What exterior finish and color options are available for custom orders?
A wide range of surface finishes is available through the RAL Color System, allowing precise color matching. In addition, texture options including Wood Grain, Marble, and Industrial Metal finishes can be applied to the exterior panels, enabling the unit to blend with various architectural aesthetics or site requirements.